TECHNICAL SPECIFICATIONS / EN 16511 / SPC |
---|
PRODUCT SPECIFICATION | STANDART | 4 mm 0,30mm SPC Click |
4 mm 0,55 mm. SPC Click |
|
---|---|---|---|---|
Total Thickness | ISO 24337 | 4,00 mm | 4,00 mm | |
Thickness of Wear Layer | 0,30 mm | 0,55 mm | ||
Total Weight | EN ISO 23997 | 7.850 kg/m2 | 7.140 kg/m2 | |
Use Classification | EN 16511 | Class 23 / Class 33 | Class 23 / Class 34 | |
Plank Size | SO 24337 | Click: 177,8 x 1219,2 mm. Click: 228,6 x 1219,2 mm. |
Click : 177,8 x 1219,2 mm. Click : 228,6 x 1219,2 mm. |
|
Packaging Per Carton:Planks | Click: 177,8x 1219,2 mm, 2,167 m2 10 pcs. Click: 228,6x 1219,2 mm, 2,230 m2 8 pcs. |
Click: 177,8 x 1219,2 mm, 2,167 m2 10 pcs. Click: 228,6x 1219,2 mm, 2,230 m2 8 pcs. |
||
Underlayment optionally IXPE | + 1mm IXPE Underlay | + 1mm IXPE Underlay | ||
Surface treatment (UV) | Yes | Yes | ||
Beveled Edges | Yes - Micro Bevel | Yes - Micro Bevel | ||
Dimensional Stability | EN-ISO 23999 | ≤0,15% | ≤0,15% | |
Reaction to Fire | EN 13501-1 | BFL-S1 | BFL-S1 | |
Residual Indentation | ISO 24343-1 | ≤ 0,05 mm | ≤ 0,05 mm | |
Furniture Leg | ISO 4918 - EN 425 | No damage | No damage | |
Castor Chair | EN-ISO 23999 | No change | No change | |
Locking Strength | ISO 24334 | Longitudinal joint: 3.7 kN/m, Trans joint 3.6 kN/m. |
Longitudinal joint: 3.4 kN/m, Trans joint 3.6 kN/m. |
|
Impact Sound Reduction with 1mm IXPE Underlay |
EN ISO 717-2 | 21 dB | 19 dB | |
Light Fastness | EN ISO 105-B02 | 6 | 6-7 | |
Resistance to Staining | EN 438-2 | Groups 1 - 3: grade 5 | Groups 1 - 3: grade 5 | |
Micro Scratch Resistance | EN 16094 | MSR-A2 | MSR-A2 | |
Impact Resistance | EN 13329 Annex F | > 1800 mm | > 1800 mm | |
Abrasion Resistance | EN 13329 Annex E | ≥ 2000 cycles | ≥ 4000 cycles | |
Thermal Resistance | EN 12664 | 0,0160 m2 K/W | 0,0177 m2 K/W | |
Slip Resistance | DIN 51130 EN 13893 |
R9 μ≥ 0,30 DS |
R9 μ≥ 0,30 DS |
|
Static Electrical Loading | EN 1815 | ≤2kV | ≤2kV | |
Formaldehyde | EN 717-1:2014 | E1 (Formaldehyde Free) | E1 (Formaldehyde Free) | |
STC Sound Testing with 1mm IXPE Underlay |
ASTM 492-09 | - | STC 52 | |
IIC Sound Testing with 1mm IXPE Underlay |
ASTM E 989-18 | - | IIC 55 | |
Pentachlorophenol (PCP) | CP 491510-01 | PCP Free | PCP Free | |
Floor Heating System | Yes suitable, see separate installation instructions. |
Max. 29° C | Max. 29° C | |
FloorScore | Indoor Air Quality Certified to SCS-EC10.3-2014 v4.0 |
SCS-FS-05915 | SCS-FS-05915 | |
TVOC | EN 16516 , ISO 16000 | A+ | A+ |